Renovia SystemInstallation Guide
Table of ContentsIntroduction Page 3NV-RVM Main Source Hub Front Panel Features Page 4NV-RVM Main Source Hub Back Panel Features Page 5
3IntroductionAbout Home Plug TechnologyThe Renovia System brings the best of NuVoNet audio control to the existing home market in a dramatic way. At t
POWERRENOVIA Main Main Sourc e HubNV-RVMRA DIO DATA SY STEMSTANDBY AUDIOSTREAMCTLTXCTLRXNuVoNetUSB123 4567NV-RVM Main Main Source Hub Front Panel Feat
5NV-RVM Main Source Hub Back Panel Features1. System On: This mono 3.5 mm voltage output is designed to emit 5 volts (no-load) when a zone is turne
6NV-I8GCP Dual Gang Control Pad Features1. Source Indicator: This indicates the current audio source playing in that zone. Source names can be cus
7M3A1:193:482 OF 2-Follow th...drift-Edge of Tom123456789101112NV-E6GCP Single Gang Control Pad Features1. Source Indicator: This indicates the cu
1234567 8910111215 14 13NV-CTP36 Color Touch Pad Features1. Source Display: This full color touch pad provides crucial information about the select
91234567891011OKMENU ZONEdriftM3A1 of 9Follow the Day3:09 PM3:481:28Edge of TomorrNV-WCPS Wireless Control Pad Features1. Selected Source: A three
101.0. Using the NV-RVSAT Site Analysis ToolThe Site Analysis Tool is an essential test prior to installing the Renovia System. All outlets and the r
11f. Select MENU – Increment SITE #, then select YES and press OK. This will start a fresh analysis log for this installation’s site analysis test.1.
12Fig. 2Site Analysis Tool, ZONERENOVIAMENUOKSi t e 1 8:5 6 P MHu b : Ent e rta inm e nt ro o m #3Zo n e: Ot h er #1Pr e ss OK t o
134. If a highly desirable outlet tests Poor or Marginal, look again for possible unfiltered Interference sources. They are normally on the same cir
142.0. Installing the In-wall NV-RVM Renovia Main Source Hub and Audio SourcesThe Renovia Main Source Hub is the central source input for all sources
15TM2.2.2 Adding the NV-SCH1 or other Sirius Connect tuner devicesNuVo offers a SIRIUS Satellite Radio receiver module, NV-SCH1, produced by a third-
162.2.3 Including the NV-RVIPD NuVoDockRenovia features Source 3 and 4 inputs for the Renovia NuVoDock for iPod. This is an easy way to incorporate iP
3.0. Installing the NV-RVZA50 Zone Amplifier and the NV-RVZA50PS Power SupplyThe Renovia Power Supply is to be installed by a certified electrician on
Fig. 15: EIA 568A wiring scheme for CAT5 CablePin #1. Green Stripe2. Green3. Orange Stripe4. Blue5. Blue Stripe6. Orange7. Brown Stripe8. Br
An inset plug on the Power Supply will mate with a plug on the Zone Amplifier. Once in place, secure the Zone Amplifier to the Power Supply with four
20Line InputThe NV-RVFZA50S has a built-in “Line Input” on the back panel. This is a very useful feature for allowing the internal 50W zone amplifier
Fig. 2312D34C5B6A7 8AUDIO STREAMCONTROLZONERSTPWRLook for the Control LED to flash indicating the set HomePlug Channel.Cycle the Power button andLoo
226.0. Using the Configurator Software6.1 Main StartupThe Start tab is the beginning point for any configuration, whether you are starting from scra
23Fig. 27+- POWER12VDC/0.4ACONNECT TO PCCONNECT TOCONCERTO D IREMITTER IRBLASTERConcerto Learning StationModel NV-I8DLSPASSTHRURE
24Fig. 28When the remote code is entered, the IR Library Record window will go from yellow to green and indicate that the capture was successful, then
256.2.6 IR Library Test (as shown in Fig. 30)An important feature of the Renovia Configurator is the ability to test each IR code as it is added to t
266.3. Sources Tab (as shown in Fig. 32)The “Sources” tab allows you to define the source component attached to each of the six source inputs. All si
276.3.2 Adding a NuVoNet Source (as shown in Fig. 34)NuVoNet sources can be placed in the Configuration with the same procedure as third party IR cont
28Fig. 36To create a preset macro, double click on the first available preset macro selection. This will open the Edit Macro Definition window. Once i
296.4.3 Control Macros An additional option within the Macro tab is the ability to establish multiple control macros. These macros are intended for i
30Exclusive Source Control: Checking this box gives this zone exclusive “do not disturb” control of any chosen source. Other zones will have the abili
31Fig. 39Slave To: This drop-down menu is used to assign additional “slave” Control Pads to a zone. Up to 20 Control Pads can be used in an installat
GROUNDCLAMPSELECTRICSERVICE ENTRANCEANTENNA DISCHARGE UNIT NEC SECTION810-20GROUNDING CONDUCTORSGROUND CLAMPSPOWER SERVICE GROUPING ELECTRODESYSTEM N
326.6.2 External Mute: Paging Trigger The Renovia System has a built-in solution for whole-house paging, typically through a phone system. The Paging
336.7. Update System The finished configuration is now ready to be downloaded to the Renovia Main Source Hub. Connect your computer to the USB input
347.0. Control Pad Setup7.1 Factory New InstallationThe installed Control Pads, NV-E6GCP, NV-I8GCP, NV-CTP36 are designed to automatically recognize
35POWERSETUPFig. 45Fig. 46MENU ZONE Zone Button Enabled DisabledFig. 47MENUMENUZONEZONE Searching forCoordinator...Press SETUP Buttonon CoordinatorT
367.4 Renovia Tuner ControlControl of Renovia’s internal tuners (sources 1 and 2) default to the buttons of the Control Pads, unless those sources ar
378.0. Using the Control Pad's MENU ButtonMenu gives access to specific music selection and control for each source, as well as zone and system
38 My Presets 1Edit Presets My Presets 1 My Presets 2 My Presets 3 My Presets 4 My Presets 5My Presets 1 1: AM 530 2: 3: 4: 5: 6:Assign Preset Assign
39Fig. 61Fig. 60AM Threshold Level 1 Level 2 Level 3Enabled Bands AM Tuners A and B FM Tuner A and B SIRIUS Tuner A SIRIUS Tuner BAntenna Po
40Diagnostics Version Signal Strength Audio TestAM/FM Strenght RSSI: 60dBuV SNR: 31 dBSIRIUS Strength SAT: Strong TERR: None Combined: StrongAre You S
418.4 Advanced Zone Control: Advanced Zone Control is designed for user access to temporary zone settings. Each of the zone parameters set in advanc
428.5 Zone Settings: This selection contains several zone specific controls, as shown in Fig. 72. Note that Advanced is grayed out and is preceded b
43Initial VolumeSet (current volume)Reset (-60 dB)Fig. 738.6 Advanced Zone Settings: These are parameters for each zone. They can be easily establi
44Fig. 76Slaved To ZoneNoneKitchenDining RoomMaster BedroomMaster BathGuest RoomNurseryZone Number: Each zone must be assigned a number or specific zo
45System SettingsDate/Time24 Hour Time DisplayPower-Off ModeFig. 78*AdvancedAdvanced: Within the System settings menu are advanced functions intended
46External Mute/Page: The EXT. MUTE input on the back panel of Renovia has a dual function. In normal mode, it is designed for the Mute Interface, NV-
479.0. Renovia Accessories9.1 The NV-I8DLS IR Learning Station InterfaceConcerto Learning StationModel NV-I8DLSPASSTHRUREADYIR SENSORTEST ACTIVEPOWE
48Capturing IR codes using the IR Learning Station Interface (as shown in Fig. 81)The Renovia Configurator Software is designed to store IR codes for
49MUTE INTERFACEADAPTER NV-MI1CONNECT TO MUTE INPUTABABDOORBELL 1DOORBELL 2Connect to Telephone RJ-11 Line 1: Pins 3,4 Line 2: Pins 2,5
50HOLDALL OFFNV-GRC1REMOTE CONTROLFAVORITESVOLUME123456789111012SOURCE/OKPWRMUTESLEEPDISPMENUG2G1F1 F2F3 F4123456789101112139.3 NV-GRC1 Remote Contro
51Renovia SpecificationsRenovia Zone NV-RVZA50PS Power SupplyPower RequirementsPower Input 95-130VAC 60HzPower Consumption Maximum 85VA (85W)Po
ENGLISHDangerExposure to extremely high noise levels may cause a permanent hearing loss. Individuals vary considerably to noise induced hearing loss b
52Renovia NV-RVZA50 In-wall Zone AmplifierLocal Source Audio Input / Line OutputRJ45 Digital to Line In/Out AccessoryNuVoNetLocal NuVoNet Control Pad
53TroubleshootingSymptom Probable CauseRemedyOne of the zone Control Pads displays a “NuVoNet Not Detected” message.Zone CAT5 is plugged into the Acce
54TroubleshootingThe IR repeater does not properly control the audio source equipment.The NuVo IR output is not set at the best carrier frequency.With
www.nuvotechnologies.comNuVo Technologies LLC Hebron, Kentucky USA NVRV 1044
FRENCHDURE EN HEURES PAR JOUR 8 6 4 3 2 1INIVEAU SONORE CONTINU EN dB 90 93 95 97 100 103DangerL‘expositi
Renovia Quick Start Guide 1. Test site with the SAT tool.a. Determine desired location for Renovia Hub.b. Connect filters to known Renovia enemie
Commenti su questo manuale